System: LPS64-30/2 (30 MIN | 40dB)
Consisting of 64 mm Siniat Drywall steel studs inserted at 600 mm centres into 65 mm Drywall steel track at top and bottom and clad both sides with 12mm Taper-edge Siniat plasterboard fixed with 25 mm Drywall screws spaced at 220 mm centres. Stagger joints between boards. All joints to be taped and jointed as per manufacturer’s instructions.
System: LPF64-60/1 (60 MIN | 40 dB)
Consisting of 64 mm Siniat Drywall steel studs inserted at 600 mm centres into 65 mm Drywall steel track at top and bottom and clad both sides with 15mm Taper-edge Siniat Fire check board fixed with 25 mm Drywall screws spaced at 220 mm centres. Stagger the plasterboard joints in the system.. All joints are to be taped and jointed in accordance with manufacturer’s specifications.
System: LPF64-60/2 (60 MIN | 45 dB)
Consisting of 64 mm Siniat Drywall steel studs inserted at 600 mm centres into 65 mm Drywall steel track at top and bottom and clad both sides with two layers of 12 mm Taper-edge Siniat plasterboard with base layer fixed with 25 mm Drywall screws spaced at 220 mm centres and face layer fixed using 41 mm Drywall screws at 220 mm centres. Stagger joints between all boards. Face layer joints to be taped and jointed in accordance with manufacturer’s specifications.
System: LPF64-120/1 (120 MIN | 48 dB)
Consisting of 64 mm Siniat Drywall steel studs inserted at 600 mm centres into 65 mm steel Drywall track at top and bottom, clad on both sides with a 12,5 mm Taper-edge Siniat Fire check Board. Base layer fixed with 25 mm Drywall screws at 220 mm centres, 0,5 mm galvanized steel sheet and a 12,5 mm face layer Siniat Fire check board fixed using 41 mm Drywall screws at 220 mm centres. Stagger joints between boards. Face layer joints to be taped and jointed in accordance with manufacturer’s specifications.
Download Full Specification